- Meeting abstract
- Open access
- Published:
Comparative analysis of established and new biosensors for cyclic nucleotides
BMC Pharmacology and Toxicology volume 16, Article number: A68 (2015)
Background
Cyclic guanosine monophosphate (cGMP) and cyclic adenosine monophosphate (cAMP) are versatile second messengers relevant to many physiological and pathophysiological conditions. Live-cell imaging of these cyclic nucleotides with biosensors allows to elucidate their levels and dynamics under close-to-native conditions. However, in order to monitor cGMP and cAMP signals in parallel in the same cell, the respective biosensors must be spectrally compatible. We have characterised some commonly used as well as novel “green” and “red” biosensors for cGMP and cAMP with regard to their sensitivity and specificity.
Methods
We used primary vascular smooth muscle cells (VSMCs) from mouse aortae to compare different cyclic nucleotide sensors. In intact VSMCs, cGMP was elevated by nitric oxide or natriuretic peptides and the signal/noise-ratio of each sensor and its sensitivity for each stimulator were analysed. To test the sensors’ sensitivity and specificity for cGMP versus cAMP, we permeabilised the cells with β-escin and applied defined concentrations of cyclic nucleotides. Furthermore, we cloned novel variants of the original CFP/YFP-based cytosolic cGi500 biosensor [1] including a membrane-targeted version termed “mcGi500” and a “red” variant termed “red cGi500” that contains the fluorophores tSapphire and Dimer2.
Results
The fluorescence resonance energy transfer (FRET)-based ratiometric biosensor cGi500 turned out to be very reliable and suitable not only for cGMP imaging in cultured VSMCs, but also in living tissues of cGi500 transgenic mice [2] as assessed by spinning disk confocal FRET imaging. Confirming previous results by Russwurm and colleagues [1], the cGi500 sensor showed a good signal/noise-ratio, an EC50 value of 500 nM for cGMP, and a high selectivity for cGMP over cAMP ( 100-fold). Its membrane-targeted version, mcGi500, as well as the non-ratiometric cGMP sensor, FlincG3 [3], showed similar properties as cGi500. The “red” cGMP sensor, red cGi500, displayed similar properties as the “green” cGi500 and – at least in VSMCs – showed a better signal/noise-ratio than the previously described “red” cGMP sensor, red cGES-DE5 [4]. Additionally, we have characterised the “green” FRET-based cAMP sensor Epac1-camps [5] in VSMCs. This sensor showed a good signal/noise-ratio and its selectivity for cAMP over cGMP was 10 fold.
Conclusion
Based on our comparative analyses, we conclude that the FRET-based ratiometric “green” cGi500 as well as its membrane-targeted version, mcGi500, and its “red” variant, red cGi500, should be useful tools for a broad spectrum of applications requiring real-time monitoring of cGMP signals. For example, mcGi500 could be used to visualise membrane-associated cGMP compartments and red cGi500 could be combined with the “green” Epac1-camps to study the crosstalk between cGMP and cAMP signalling in living cells and tissues.
References
Russwurm M, Mullershausen F, Friebe A, Jager R, Russwurm C, Koesling D: Design of fluorescence resonance energy transfer (FRET)-based cGMP indicators: a systematic approach. Biochem J. 2007, 407 (Pt 1): 69-77.
Thunemann M, Wen L, Hillenbrand M, Vachaviolos A, Feil S, Ott T, et al: Transgenic mice for cGMP imaging. Circ Res. 2013, 113 (4): 365-371. 10.1161/CIRCRESAHA.113.301063.
Bhargava Y, Hampden-Smith K, Chachlaki K, Wood KC, Vernon J, Allerston CK, et al: Improved genetically-encoded, FlincG-type fluorescent biosensors for neural cGMP imaging. Front Mol Neurosci. 2013, 6: 26-
Niino Y, Hotta K, Oka K: Simultaneous Live Cell Imaging Using Dual FRET Sensors with a Single Excitation Light. PLoS One. 2009, 4 (6): e6036-10.1371/journal.pone.0006036.
Nikolaev VO, Bunemann M, Hein L, Hannawacker A, Lohse MJ: Novel single chain cAMP sensors for receptor-induced signal propagation. J Biol Chem. 2004, 279 (36): 37215-37218. 10.1074/jbc.C400302200.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
About this article
Cite this article
Milde, M., Thunemann, M., Subramanian, H. et al. Comparative analysis of established and new biosensors for cyclic nucleotides. BMC Pharmacol Toxicol 16 (Suppl 1), A68 (2015). https://doi.org/10.1186/2050-6511-16-S1-A68
Published:
DOI: https://doi.org/10.1186/2050-6511-16-S1-A68